Our pursuit and company intention is usually to "Always fulfill our purchaser requirements". We go on to acquire and layout excellent high quality products for both our previous and new consumers and realize a win-win prospect for our customers too as us for Track Power Meter , Energy Analyzer Meter , Solar Electric Meter , Objects won certifications together with the regional and international primary authorities. For far a lot more detailed information, make sure you make contact with us!
Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN Detail:

Technical Parameter

1. Single phase AC input
Voltage range: 100V, 220V, 380V, etc.
Current range: 5A, 50a, etc; The model of external opening current transformer is optional.
Signal processing: special metering chip is adopted, and 24 bit AD is adopted.
Overload capacity: 1.2 times the range is sustainable; The instantaneous (<20ms) current is 5 times, the voltage is 1.2 times, and the range is not damaged.
Input impedance: voltage channel >1k Ω /v.

2. Communication interface
Interface type: 1-way RS-485 communication interface.
Communication protocol: MODBUS-RTU protocol.
Data format: software can set “n, 8,1″, “E, 8,1″, “O, 8,1″, “n, 8,2″.
Communication rate: the baud rate of RS-485 communication interface can be set to 9600, 19200, 38400bps; The baud rate defaults to 9600bps.

3. Test output data
Voltage, current, power, electric energy and other electrical parameters.

4. Measurement accuracy
Voltage, current and power: ± 1.0%; Active kwh is level 1.

5. Electrical isolation
RS-485 interface is isolated from AC power supply, voltage input and current input; Isolation withstand voltage 2000vac.

6. Power supply
Power supply mode: the voltage range is ac85~265
Typical power consumption: ≤ 1W.

7. Working environment
Working temperature: -20~+70 ℃; Storage temperature: -40~+85 ℃.
Relative humidity: 5~95%, no condensation (at 40 ℃).
Altitude: 0~3000 meters.
Environment: a place without explosion, corrosive gas and conductive dust, and without significant shaking, vibration and impact.

8. Temperature drift: ≤100ppm/℃.

9. Product size: 90mm*40mm.


Product detail pictures:

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures


Related Product Guide:

We now have a specialist, efficiency workforce to deliver excellent service for our purchaser. We always follow the tenet of customer-oriented, details-focused for Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN, The product will supply to all over the world, such as: Greece, Netherlands, Montpellier, Our team knows well the market demands in different countries, and is capable of supplying suitable quality products and solutions at the best prices to different markets. Our company has already set up a experienced, creative and responsible team to develop clients with the multi-win principle.
  • We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Amber from panama - 2017.12.31 14:53
    On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Murray from Atlanta - 2018.03.03 13:09

    RELATED PRODUCTS