Our concentrate on should be to consolidate and enhance the quality and service of present products, meanwhile consistently produce new products to meet unique customers' demands for Measuring Module , Esp Power Meter , Track Power Meter , Never-ending improvement and striving for 0% deficiency are our two main excellent policies. Should you need anything, never be reluctant to speak to us.
18 Years Factory Ct Power Meter - JSY-MK-138 12 channel mutual inductance electric energy metering module – JIAN SI YAN Detail:

Description

Jsy-mk-138 12 way mutual inductance electric energy metering module can be widely used in energy-saving transformation, electric power, communication, railway, transportation, environmental protection, petrochemical, steel and other industries to monitor the current and power consumption of AC equipment.

Technical Parameter

1. Single phase AC input
1) Voltage range: 100V, 220V, 380V, etc.
2) Current range: 5A, 50a, 100A, etc; The model of external opening current transformer is optional.
3) Signal processing: special metering chip is adopted, and 24 bit AD is adopted.
4) Overload capacity: 1.2 times the range is sustainable; The instantaneous (<20ms) current is 5 times, the voltage is 1.2 times, and the range is not damaged.
5) Input impedance: voltage channel >1k Ω /v.

2. Communication interface
1) Interface type: 1-way RS-485 communication interface.
2) Communication protocol: MODBUS-RTU protocol.
3) Data format: software can set “n, 8,1″, “E, 8,1″, “O, 8,1″, “n, 8,2″.
4) Communication rate: the baud rate of RS-485 communication interface can be set to 9600, 19200, 38400bps; The baud rate defaults to 9600bps.

3. Test output data
Voltage, current, power, electric energy and other electrical parameters.

4. Measurement accuracy
Voltage, current and power: ± 1.0%; Active kwh is level 1.

5. Electrical isolation
RS-485 interface is isolated from AC power supply, voltage input and current input; Isolation withstand voltage 2000vac.

6. Power supply
1) Two power supply modes are selected: take power from the input AC phase C, and note that the voltage range is ac85~265; DC power supply can also be selected, and the input range is +9v~15v.
2) Typical power consumption: ≤ 1W.

7. Working environment
1) Working temperature: -20~+70 ℃; Storage temperature: -40~+85 ℃.
2) Relative humidity: 5~95%, no condensation (at 40 ℃).
3) Altitude: 0~3000 meters.
4) Environment: a place without explosion, corrosive gas and conductive dust, and without significant shaking, vibration and impact.

8. Temperature drift
≤100ppm/℃

9. Installation method
The distance between screw fixing and installation holes is 105*58.5mm

10. Product size
268*84*46mm


Product detail pictures:

18 Years Factory Ct Power Meter - JSY-MK-138 12 channel mutual inductance electric energy metering module – JIAN SI YAN detail pictures


Related Product Guide:

Bear "Customer initially, High-quality first" in mind, we work closely with our prospects and supply them with efficient and specialist companies for 18 Years Factory Ct Power Meter - JSY-MK-138 12 channel mutual inductance electric energy metering module – JIAN SI YAN, The product will supply to all over the world, such as: Ukraine, Sweden, Jordan, We always insist on the management tenet of "Quality is first, Technology is basis, Honesty and Innovation".We are able to develop new products continuously to a higher level to satisfy different needs of customers.
  • The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Anne from Bangalore - 2017.04.18 16:45
    Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Carey from Saudi Arabia - 2017.04.18 16:45

    RELATED PRODUCTS