Wholesale Price Data Center Rack Pdu - JSY1005 Intelligent rs485pdu current meter – JIAN SI YAN

Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our pursuit and company intention is usually to "Always fulfill our purchaser requirements". We go on to acquire and layout excellent high quality products for both our previous and new consumers and realize a win-win prospect for our customers too as us for Basic Rack Pdu , Power Quality Monitor , Iqsquare Power Meter , We sincerely look forward to hearing from you. Give us a opportunity to show you our professionalism and enthusiasm. We have been sincerely welcome excellent friends from numerous circles at dwelling and overseas occur to cooperate!
Wholesale Price Data Center Rack Pdu - JSY1005 Intelligent rs485pdu current meter – JIAN SI YAN Detail:

Technical Parameter

1. Single phase AC input
1) Voltage range: 100V, 220V, 380V, etc.
2) Current range: 5A, 50a, etc; The model of external opening current transformer is optional.
3) Signal processing: special metering chip is adopted, and 24 bit AD is adopted.
4) Overload capacity: 1.2 times the range is sustainable; The instantaneous (<20ms) current is 5 times, the voltage is 1.2 times, and the range is not damaged.
5) Input impedance: voltage channel >1k Ω /v.

2. Communication interface
1) Interface type: 1-way RS-485 communication interface.
2) Communication protocol: MODBUS-RTU protocol.
3) Data format: software can set “n, 8,1″, “E, 8,1″, “O, 8,1″, “n, 8,2″.
4) Communication rate: the baud rate of RS-485 communication interface can be set to 9600, 19200, 38400bps; The baud rate defaults to 9600bps.

3. Test output data
Voltage, current, power, electric energy and other electrical parameters.

4. Measurement accuracy
Voltage, current and power: ± 1.0%; Active kwh is level 1.

5. Electrical isolation
RS-485 interface is isolated from AC power supply, voltage input and current input; Isolation withstand voltage 2000vac.

6. Power supply
1) Power supply mode: the voltage range is ac85~265
2) Typical power consumption: ≤ 1W.

7. Working environment
1) Working temperature: -20~+70 ℃; Storage temperature: -40~+85 ℃.
2) Relative humidity: 5~95%, no condensation (at 40 ℃).
3) Altitude: 0~3000 meters.
4) Environment: a place without explosion, corrosive gas and conductive dust, and without significant shaking, vibration and impact.

8. Temperature drift: ≤100ppm/℃.

9. Product size: 1U housing.


Product detail pictures:

Wholesale Price Data Center Rack Pdu - JSY1005 Intelligent rs485pdu current meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY1005 Intelligent rs485pdu current meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY1005 Intelligent rs485pdu current meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY1005 Intelligent rs485pdu current meter – JIAN SI YAN detail pictures


Related Product Guide:

With advanced technologies and facilities, strict quality control, reasonable price, superior service and close co-operation with customers, we are devoted to providing the best value for our customers for Wholesale Price Data Center Rack Pdu - JSY1005 Intelligent rs485pdu current meter – JIAN SI YAN, The product will supply to all over the world, such as: Uruguay, Uruguay, United Arab emirates, We are proud to supply our products and solutions to every costumer all around the world with our flexible, fast efficient services and strictest quality control standard which has always approved and praised by customers.
  • We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
    5 Stars By Amelia from Armenia - 2018.09.29 13:24
    The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.
    5 Stars By Pearl from Botswana - 2018.06.26 19:27

    RELATED PRODUCTS