continue to improve, to ensure product quality in line with market and customer standard requirements. Our company has a quality assurance system have been established for Charging Point , Electric Measure Meter , Dc Current Ammeter , When you've got any remarks about our firm or merchandise, please come to feel no cost to call us, your coming mail will likely be really appreciated.
Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN Detail:

Technical Parameter

1. Single phase AC input
Voltage range: 100V, 220V, 380V, etc.
Current range: 5A, 50a, etc; The model of external opening current transformer is optional.
Signal processing: special metering chip is adopted, and 24 bit AD is adopted.
Overload capacity: 1.2 times the range is sustainable; The instantaneous (<20ms) current is 5 times, the voltage is 1.2 times, and the range is not damaged.
Input impedance: voltage channel >1k Ω /v.

2. Communication interface
Interface type: 1-way RS-485 communication interface.
Communication protocol: MODBUS-RTU protocol.
Data format: software can set “n, 8,1″, “E, 8,1″, “O, 8,1″, “n, 8,2″.
Communication rate: the baud rate of RS-485 communication interface can be set to 9600, 19200, 38400bps; The baud rate defaults to 9600bps.

3. Test output data
Voltage, current, power, electric energy and other electrical parameters.

4. Measurement accuracy
Voltage, current and power: ± 1.0%; Active kwh is level 1.

5. Electrical isolation
RS-485 interface is isolated from AC power supply, voltage input and current input; Isolation withstand voltage 2000vac.

6. Power supply
Power supply mode: the voltage range is ac85~265
Typical power consumption: ≤ 1W.

7. Working environment
Working temperature: -20~+70 ℃; Storage temperature: -40~+85 ℃.
Relative humidity: 5~95%, no condensation (at 40 ℃).
Altitude: 0~3000 meters.
Environment: a place without explosion, corrosive gas and conductive dust, and without significant shaking, vibration and impact.

8. Temperature drift: ≤100ppm/℃.

9. Product size: 90mm*40mm.


Product detail pictures:

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures


Related Product Guide:

We usually continually offer you the most conscientious consumer services, along with the widest variety of designs and styles with finest materials. These initiatives include the availability of customized designs with speed and dispatch for Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN, The product will supply to all over the world, such as: Orlando, USA, Victoria, We strive for excellence, constant improvement and innovation, is committed to make us the "customer trust" and the "first choice of engineering machinery accessories brand" suppliers. Choose us, sharing a win-win situation!
  • The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Roland Jacka from Kenya - 2018.02.21 12:14
    The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Julie from Istanbul - 2018.10.01 14:14

    RELATED PRODUCTS