It is a good way to enhance our products and solutions and repair. Our mission will be to build creative solutions to consumers with a great experience for Wireless Energy Monitor , Ammeter Current Voltmeter , Dc Charge Spots , We are able to do your tailored get to fulfill your own satisfactory! Our organization sets up several departments, including manufacturing department, sales department, high quality control department and sevice center, etc.
Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN Detail:

Technical Parameter

1. Single phase AC input
Voltage range: 100V, 220V, 380V, etc.
Current range: 5A, 50a, etc; The model of external opening current transformer is optional.
Signal processing: special metering chip is adopted, and 24 bit AD is adopted.
Overload capacity: 1.2 times the range is sustainable; The instantaneous (<20ms) current is 5 times, the voltage is 1.2 times, and the range is not damaged.
Input impedance: voltage channel >1k Ω /v.

2. Communication interface
Interface type: 1-way RS-485 communication interface.
Communication protocol: MODBUS-RTU protocol.
Data format: software can set “n, 8,1″, “E, 8,1″, “O, 8,1″, “n, 8,2″.
Communication rate: the baud rate of RS-485 communication interface can be set to 9600, 19200, 38400bps; The baud rate defaults to 9600bps.

3. Test output data
Voltage, current, power, electric energy and other electrical parameters.

4. Measurement accuracy
Voltage, current and power: ± 1.0%; Active kwh is level 1.

5. Electrical isolation
RS-485 interface is isolated from AC power supply, voltage input and current input; Isolation withstand voltage 2000vac.

6. Power supply
Power supply mode: the voltage range is ac85~265
Typical power consumption: ≤ 1W.

7. Working environment
Working temperature: -20~+70 ℃; Storage temperature: -40~+85 ℃.
Relative humidity: 5~95%, no condensation (at 40 ℃).
Altitude: 0~3000 meters.
Environment: a place without explosion, corrosive gas and conductive dust, and without significant shaking, vibration and impact.

8. Temperature drift: ≤100ppm/℃.

9. Product size: 90mm*40mm.


Product detail pictures:

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures


Related Product Guide:

"Based on domestic market and expand overseas business" is our development strategy for Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN, The product will supply to all over the world, such as: Amman, Turkmenistan, Pretoria, We are always creating new technology to streamline the production, and provide goods with competitive prices and high quality! Customer satisfaction is our priority! You can let us know your idea to develop unique design for your own model to prevent too much similar parts in the market! We will offer our best service to satisfy all your needs! Please contact us right away!
  • Hope that the company could stick to the enterprise spirit of "Quality, Efficiency, Innovation and Integrity", it will be better and better in the future.
    5 Stars By Nicole from Bangladesh - 2018.05.22 12:13
    High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Debby from Mauritius - 2018.06.12 16:22

    RELATED PRODUCTS