Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN

Description:


Product Detail

Product Tags

Related Video

Feedback (2)

That has a positive and progressive attitude to customer's interest, our organization consistently improves our products quality to satisfy the demands of shoppers and further focuses on safety, reliability, environmental specifications, and innovation of Electric Energy Instruments Scheme Development , Dc Charge Spots , Single Phase Power Meter , We have deep cooperation with hundreds of factories around China. The products we provide can match with your different demands. Choose us, and we won't make you regret!
Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN Detail:

Technical Parameter

1. Single phase AC input
Voltage range: 100V, 220V, 380V, etc.
Current range: 5A, 50a, etc; The model of external opening current transformer is optional.
Signal processing: special metering chip is adopted, and 24 bit AD is adopted.
Overload capacity: 1.2 times the range is sustainable; The instantaneous (<20ms) current is 5 times, the voltage is 1.2 times, and the range is not damaged.
Input impedance: voltage channel >1k Ω /v.

2. Communication interface
Interface type: 1-way RS-485 communication interface.
Communication protocol: MODBUS-RTU protocol.
Data format: software can set “n, 8,1″, “E, 8,1″, “O, 8,1″, “n, 8,2″.
Communication rate: the baud rate of RS-485 communication interface can be set to 9600, 19200, 38400bps; The baud rate defaults to 9600bps.

3. Test output data
Voltage, current, power, electric energy and other electrical parameters.

4. Measurement accuracy
Voltage, current and power: ± 1.0%; Active kwh is level 1.

5. Electrical isolation
RS-485 interface is isolated from AC power supply, voltage input and current input; Isolation withstand voltage 2000vac.

6. Power supply
Power supply mode: the voltage range is ac85~265
Typical power consumption: ≤ 1W.

7. Working environment
Working temperature: -20~+70 ℃; Storage temperature: -40~+85 ℃.
Relative humidity: 5~95%, no condensation (at 40 ℃).
Altitude: 0~3000 meters.
Environment: a place without explosion, corrosive gas and conductive dust, and without significant shaking, vibration and impact.

8. Temperature drift: ≤100ppm/℃.

9. Product size: 90mm*40mm.


Product detail pictures:

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures

Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN detail pictures


Related Product Guide:

We are convinced that with joint endeavours, the small business between us will bring us mutual benefits. We could assure you products quality and competitive selling price for Wholesale Price Data Center Rack Pdu - JSY-MK-164 Control type intelligent PDU meter – JIAN SI YAN, The product will supply to all over the world, such as: Sao Paulo, Washington, Manchester, We'll supply much better products with diversified designs and expert services. We sincerely welcome friends from over the world to visit our company and cooperate with us on the basis of long-term and mutual benefits.
  • The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Carey from Doha - 2017.08.18 11:04
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Annabelle from Qatar - 2017.11.12 12:31

    RELATED PRODUCTS