Good Quality Piles - JSY-MK-183 AC charging pile multi-channel measurement and zero line current acquisition module – JIAN SI YAN

Description:


Product Detail

Product Tags

Related Video

Feedback (2)

As a way to present you with ease and enlarge our enterprise, we also have inspectors in QC Workforce and assure you our greatest support and solution for Harmonic Meter , Power quality monitoring , Energy Consumption Monitor Device , Our concept would be to assist presenting the confidence of each prospective buyers while using the offering of our most honest service, as well as right merchandise.
Good Quality Piles - JSY-MK-183 AC charging pile multi-channel measurement and zero line current acquisition module – JIAN SI YAN Detail:

Description

Jsy-mk-183 AC 8-channel temperature measurement and zero line current acquisition module can be widely used in charging pile, energy-saving transformation, power, communication, railway, transportation, environmental protection, petrochemical, iron and steel and other industries to monitor the AC and power consumption of AC equipment.

Technical Parameter

1. AC 8-way input
1) Voltage range: 0~350v (customizable).
2) Current range: 10A per circuit (customizable).
3) Signal processing: special metering chip is adopted, and 24 bit AD is adopted.
4) Overload capacity: 1.2 times the range is sustainable; The instantaneous (<20ms) current is 5 times, the voltage is 1.2 times, and the range is not damaged.
5) Input impedance: voltage channel >1k Ω /v, current channel ≤ 10m Ω.

2. Communication interface
1) Interface type: 2-way RS-485 communication interface.
2) Communication protocol: MODBUS-RTU protocol.
3) Data format: software can set “n, 8,1″, “E, 8,1″, “O, 8,1″, “n, 8,2″.
4) Communication rate: the baud rate of RS-485 communication interface can be set to 9600, 19200, 38400bps; The baud rate is 9600bps by default, and the data format is “n, 8,1″.

3. Test output data
Voltage, current, power, electric energy, zero line current and other electrical parameters.

4. Measurement accuracy
Voltage, current and power: ± 1.0%; Active kwh is level 1.

5. Electrical isolation
RS-485 interface, which is isolated from the power supply and each measured power supply; Isolation withstand voltage 1000VAC.

6. Power supply
1) Dc9~50v wide range power supply.
2) Typical power consumption: 165ma (12V).

7. Working environment
1) Working temperature: -20~+70 ℃; Storage temperature: -40~+85 ℃.
2) Relative humidity: 5~95%, no condensation (at 40 ℃).
3) Altitude: 0~3000 meters.
4) Environment: a place without explosion, corrosive gas and conductive dust, and without significant shaking, vibration and impact.

8. Temperature drift: ≤100ppm/℃.

9. Product size: 252.8*80mm.


Product detail pictures:

Good Quality Piles - JSY-MK-183 AC charging pile multi-channel measurement and zero line current acquisition module – JIAN SI YAN detail pictures


Related Product Guide:

Our personnel are generally within the spirit of "continuous improvement and excellence", and using the excellent top quality goods, favorable rate and superior after-sales expert services, we try to win every customer's believe in for Good Quality Piles - JSY-MK-183 AC charging pile multi-channel measurement and zero line current acquisition module – JIAN SI YAN, The product will supply to all over the world, such as: Manchester, Brazil, Barbados, Our products are widely recognized and trusted by users and can meet continuously changing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
  • A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Cora from Cologne - 2018.07.12 12:19
    It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Caroline from Germany - 2017.03.28 12:22

    RELATED PRODUCTS