We constantly think and practice corresponding to the change of circumstance, and grow up. We aim at the achievement of a richer mind and body along with the living for Power Reflection Meter , Ftth Power Meter , Power Metering System , We will keep working hard and as we try our best to supply the best quality products, most competitive price and excellent service to every customer. Your satisfaction, our glory!!!
Factory directly Reactive Power Meter - JSY-MK-138 12 channel mutual inductance electric energy metering module – JIAN SI YAN Detail:

Description

Jsy-mk-138 12 way mutual inductance electric energy metering module can be widely used in energy-saving transformation, electric power, communication, railway, transportation, environmental protection, petrochemical, steel and other industries to monitor the current and power consumption of AC equipment.

Technical Parameter

1. Single phase AC input
1) Voltage range: 100V, 220V, 380V, etc.
2) Current range: 5A, 50a, 100A, etc; The model of external opening current transformer is optional.
3) Signal processing: special metering chip is adopted, and 24 bit AD is adopted.
4) Overload capacity: 1.2 times the range is sustainable; The instantaneous (<20ms) current is 5 times, the voltage is 1.2 times, and the range is not damaged.
5) Input impedance: voltage channel >1k Ω /v.

2. Communication interface
1) Interface type: 1-way RS-485 communication interface.
2) Communication protocol: MODBUS-RTU protocol.
3) Data format: software can set “n, 8,1″, “E, 8,1″, “O, 8,1″, “n, 8,2″.
4) Communication rate: the baud rate of RS-485 communication interface can be set to 9600, 19200, 38400bps; The baud rate defaults to 9600bps.

3. Test output data
Voltage, current, power, electric energy and other electrical parameters.

4. Measurement accuracy
Voltage, current and power: ± 1.0%; Active kwh is level 1.

5. Electrical isolation
RS-485 interface is isolated from AC power supply, voltage input and current input; Isolation withstand voltage 2000vac.

6. Power supply
1) Two power supply modes are selected: take power from the input AC phase C, and note that the voltage range is ac85~265; DC power supply can also be selected, and the input range is +9v~15v.
2) Typical power consumption: ≤ 1W.

7. Working environment
1) Working temperature: -20~+70 ℃; Storage temperature: -40~+85 ℃.
2) Relative humidity: 5~95%, no condensation (at 40 ℃).
3) Altitude: 0~3000 meters.
4) Environment: a place without explosion, corrosive gas and conductive dust, and without significant shaking, vibration and impact.

8. Temperature drift
≤100ppm/℃

9. Installation method
The distance between screw fixing and installation holes is 105*58.5mm

10. Product size
268*84*46mm


Product detail pictures:

Factory directly Reactive Power Meter - JSY-MK-138 12 channel mutual inductance electric energy metering module – JIAN SI YAN detail pictures


Related Product Guide:

Our firm sticks on the theory of "Quality will be the life in the enterprise, and status could be the soul of it" for Factory directly Reactive Power Meter - JSY-MK-138 12 channel mutual inductance electric energy metering module – JIAN SI YAN, The product will supply to all over the world, such as: Montpellier, India, United States, We have a dedicated and aggressive sales team, and many branches, catering to our customers. We are looking for long-term business partnerships, and ensure our suppliers that they will definitely benefit in both short and long run.
  • In our cooperated wholesalers, this company has the best quality and reasonable price, they are our first choice.
    5 Stars By Maud from Serbia - 2017.12.02 14:11
    Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
    5 Stars By Danny from Latvia - 2017.11.29 11:09

    RELATED PRODUCTS